4.2 What cooling and the case do

Lesson
Hardware safety: isolate power; never open a PSU.

Before touching hardware

  • Follow the exact model's service instructions. Shut down, unplug mains and peripherals, and disconnect any internal battery as instructed. Sleep, the PSU switch, or unplugging a laptop charger alone does not fully isolate power.
  • Let parts cool. Use a clean, dry workspace and approved ESD precautions. Hold boards by their edges, avoid contacts, account for screws, and never force connectors.
  • Never open a PSU or insert tools through its vents; stored energy can remain after unplugging. Use only modular cables confirmed compatible with the exact PSU model.
  • Isolate power before every physical change or cleaning. Powered tests are software/external observations with hands and tools out. No live probing, unspecified pin bridging, or damaged-battery servicing.
  • Stop for damage, swelling, liquid, burning smells, or unclear instructions; consult qualified service. Photos, diagrams, and supplied readings are sufficient for these exercises.

Service and ESD guidance · Example PSU cable chart. Check your exact model.

Practice lab

0 / 1solved

Saved on this device. Practice is ungraded.

Build and test

Quiet an overheating office PC

An office PC runs hot and its fans disturb nearby staff. The case photo shows front intake, rear exhaust, and a box blocking the front vent. Plan clearance and fans to keep heat retention at most 3 and noise at most 4 in the supplied model. These indices are not temperatures or manufacturer limits.

Heat-retention index—
Noise index—

Change choices to compare results, then check the requirements.

  • Heat retention at most 3
  • Noise index at most 4
Lesson notes

Cooling removes heat; the case mounts and protects parts while guiding airflow.

Heat removal

Fans move air and heatsinks move heat away from chips. Inadequate cooling can cause throttling, instability, or protective shutdown.

An open airflow path

Cool air needs a route in and warm air a route out. Fan direction, vents, and obstructions affect that route; more fans alone may not solve a blockage.

Case structure

The case protects and mounts components, routes airflow, and provides access to buttons and ports.

Trace the route

Use a case diagram or external view to trace intake and exhaust. Notice obstructions and dust. Follow the isolation procedure before any internal cleaning or fan changes.

Worked example

Inputs: A supplied airflow diagram shows intake blocked by a box; exhaust is clear.

Task: Describe a safe first improvement and a controlled observation.

Check the reasoning

Move the external obstruction without reaching inside. Observe the same workload/room conditions; isolate before internal cleaning/fan changes.

More fans do not fix every blocked path. Compare manufacturer limits and keep powered testing hands-off.

Cool air inComponentsWarm air out
Keep intake and exhaust clear so air crosses heat sources. Follow the case and component instructions.